03 / 10
CHAKRAVAT
Fully Modular Programmable Induction Port, Mouthpiece & DUSA Tube Shaker
04 / 10
Cascade Impactors
Stainless Steel & Aluminum
08 / 10
Electronic Metered Dose Inhaler
10 / 10
STS-1000i
Automated sample transfer from test tubes to HPLC vials
Building test automation since
2006
Documents with every system
Validation
A3G Configurations
The A3G configures easily to work with pMDI, Nasal and DPI products.
Instruments built for regulated laboratories
A3G
Automated Andersen Cascade Impactor
View details →
PRANA
Automated pMDI & Nasal Shaker / Actuator
View details →
CHAKRAVAT
Programmable Induction Port Shaker
View details →
STS-1000i
Automated sample transfer to HPLC vials
View details →
Cascade Impactors
Stainless steel & aluminium
View details →
Accessories
For ACI & NGI systems
View details →The mass balance data, published and reviewed
Investigation of Mass Balance Achieved by the Andersen Third Generation (A3G) Cascade Impactor during APSD analysis — conducted with Zydus Cadila Healthcare and published in EC Pulmonology and Respiratory Medicine, Volume 9 Issue 1.
Read the full paper
What the industry says
Regulators, academics and formulators who have seen the A3G work.
“I can truly say that I was impressed by the capabilities of A3G in generating consistent data for pMDIs. The proof is in the data shown.”
Dr. S Prasad Peri
Ex-USFDA Branch Chief; Global Quality and Regulatory Professional at Merck and Co
“A3G is the first system I have seen which offers promise of complete automation and efficient collection of reproducible data across all stages. I expect this will lead to much more efficient testing with significant cost savings.”
Dr. Richard Dalby
Professor of Pharmaceutical Sciences, University of Maryland; Co-Chair, RDD
“This will be a most awaited instrument and I am sure this instrument will be a revolution in the field of inhalation testing.”
Mr. Brajesh Thakur
General Manager, Zydus
“It is really impressive to see that automation can help to speed up such complex analysis to great extent.”
Dr. Ritu Laddha
Vice President, Zydus Cadila
Or let our lab run the study
APSD Testing Services
A3G has demonstrated that it can produce very high precision data very fast. This data has been published at t…
PRANA DUSA Tube Testing
DUSA tube testing on our own PRANA system — pMDI and nasal devices shaken, actuated and dosed into the DUSA tube, with every dose weighed and logged.
ACI & NGI Mensuration
We use state of the art portable optical systems to mensurate your ACI and NGI jet holes.
NGI Induction Port Repair
We refurbish damaged NGI and USP induction ports back to specification, so an expensive part does not have to be replaced.
Recognition
Awarded and recognised by
Tell us what you need to measure
Send the compound, the device and the guideline you are testing against — we come back with the right configuration.